ADSS Optical Fiber Cable Outdoor Aerial ADSS 48 96 144 Core G652 Optical Fiber
We have a team with strong technical strength, high professional quality and rich practical experience to provide our customers with excellent 1550 Mini Satellite Optical Transmitter, Horizontal Fiber Optic Splice Closure, H.264 Iptv Encoder. We have always been driven by the concept of 'diligence and honesty', whether in technology or sales, we have always maintained the industry leader, we provide customers with higher quality products, and continue to exceed customer expectations. We expect to promote the technological progress and innovation of our company and even the whole industry, and continue to grow in the direction of high integration, forming a collective brand effect.
Outdoor aerial optical cable ADSS
ADSS is an alternative to OPGW and OPAC with lower installation cost. The cables are designed to be strong enough to allow lengths of up to 700 metres to be installed between support towers. ADSS cable is designed to be lightweight and small in diameter to reduce the load on tower structures due to cable weight, wind, and ice.


Cable structure and parameter
SN | Item | Unit | Value | |||
1 | No. of fibers | count | 4~24 | 36/48/72 | 96 | 128/144 |
2 | No. of fibers per tube | count | 4 | 12 | 12 | 12 |
3 | No. of elements | count | 6 | 6 | 8 | 12 |
4 | Thickness of outer sheath | mm | 1.7 | 1.7 | 1.7 | 1.7 |
5 | Cable diameter(±5%) | mm | 10.8 | 11.4 | 13.0 | 16.3 |
6 | Cable weight(±10%) | kg/km | 83 | 90 | 128 | 199 |
7 | Maximum allowable tension | N | 2700 | |||
8 | Short term crush | N/100mm | 1000 | |||
9 | Span | m | 100 | |||
10 | Wind speed | Km/h | ≤35 | |||
11 | Ice thickness | mm | 0 | |||
Note: Mechanical sizes are nominal values.
Characteristic of Optical Cable
Min. bending radius for installation
Static: 10 x cable diameter Dynamic: 20 x cable diameter
2.2 Application temperature range Operation: -40℃ ~ +60℃ Installation: -10℃ ~ +60℃ Storage/transportation: -40℃ ~ +60℃
Main mechanical & environmental performance test
Item | Test Method | Acceptance Condition |
Tensile Strength IEC 60794-1-2-E1 | - Load: Maximum allowable tension - Length of cable: about 50m - Load time: 1min | - Fiber strain £ 0.33% - No fiber break and no sheath damage. |
Crush Test IEC 60794-1-2-E3 | - Load: Short term crush - Load time: 1min | - Loss change £ 0.1dB@1550nm - No fiber break and no sheath damage. |

Our product line is constantly improving the process, making the quality of our ADSS Optical Fiber Cable Outdoor Aerial ADSS 48 96 144 Core G652 Optical Fiber more popular with our customers. Welcome to patronize! Our final goal is 'To try the best, To be the Best'.
You Might Also Like
Send Inquiry